Equipped with an array of microphones for an expanded field-of-view, the handheld Fluke ii900 Industrial Acoustic Imager (Sonic Industrial Imager) enables maintenance teams to quickly and accurately locate air, gas and vacuum leaks in compressed air systems; even in noisy environments. Specifically designed for noisy production facilities the new SoundSight™ technology is simple to learn and easy to implement. The 7” LCD touchscreen overlays a SoundMap™ on a visual image for quick leak location identification. The straightforward, intuitive interface allows technicians to isolate the sound frequency of the leak to filter out loud background noise. In a matter of hours, the team can inspect the entire plant – during peak operations. For the first time, you can quickly and easily identify the air leak repairs needed to ensure efficient operations and reduce utility bills. Images can be saved and exported for reporting purposes. Never leave air leaks unattended again.
Due to global battery shortages the ii900 Precision Acoustic Imager will be shipped with 1 (one) rechargeable battery Your second battery will follow later. Sorry for any inconvenience this might cause you.
- Do more with the same air compressors – delay the capital expense of purchasing an additional compressor
- Ensure proper air pressure to your pneumatic equipment
- Lower utility costs
- Reduce leak detection time
- Improve reliability in your production line
Fluke's flagship power quality and energy monitor; shipped in hard case with voltage cables, and PC Software. With this time and labor saving feature, you can configure the instrument, receive reports and download data to your computer without ever leaving your office!
This is all you need for a host of power quality and energy studies. It can be configured with your choice of clamp-on CT's or flexible current probes. Call us for advice for the best solution for your application.
Ask about two-week rates, local pickup too. We provide up to 2 hours consulting and training included in rental price.
Package
Basic Package |
Pricing |
FLUKE 1777 Three-Phase Power Quality Analyzer Complete with the
|
Rent & Purchase: |
Electrical Characteristics
Voltage Inputs | |
Number of Inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) |
Measurement Category | 1000 V CAT III/600 V CAT IV |
Maximum Input Voltage | 1000 V rms/1000 V DC (1700 Vpk) |
Nominal Voltage Range | Wye and single phase: variable (50 to 1000 V) Delta: variable (100 to 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 to 690 V |
Input Impedance | 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE |
Bandwidth | DC to 30 kHz for PQ measurements, excluding transients |
Resolution | 24-bit synchronous sampling |
Sampling Frequency | 80 kS/second at 50/60 Hz |
Scaling | 1:1 variable for use of potential transformers |
Voltage Transients | |
Measurement Range | ±8 kV |
Sampling Rate | 1 MS/second 20 MS/second |
Bandwidth | DC to 1 MHz |
Trigger | Adjustable trigger level Triggers on high-frequency components >1.5 kHz |
Resolution | 14-bit synchronous sampling |
Current Inputs | |
Current Inputs | 4 inputs 3 phases and neutral, range selected automatically to attached sensor |
Bandwidth | DC to 30 kHz |
Resolution | 24-bit synchronous sampling |
Sampling Frequency | 80 kS/second at 50/60 Hz |
Scaling | 1:1 variable |
Input Voltage | Clamp: 50 mV/500 mV rms; CF 2.8 Rogowski coil: 15 mV/150 mV rms at 50 Hz, 18 mV/180 mV rms at 60 Hz; CF 4 All at nominal probe range |
Input Impedance | 11 kΩ |
Data Acquisition Voltage and Current | |
Input Mains Frequency | DC, 50/60 Hz ±15% (42.5 to 57.5 Hz, 51 to 69 Hz) |
Topologies | 1-φ, 1-φ IT, split phase, 3-φ delta, 3-φ wye IT, 3-φ aron/blondel (2 element delta), 3-φ delta open leg, 3-φ high leg delta |
Data Storage | 32 GB microSD card (installed) |
Memory Size | Typical 10 logging sessions of 8 weeks with 1-minute intervals and 100 events The number of possible logging sessions and logging period depends on user requirements |
Real-time Accuracy | Internal: 3 ppm (0.26 s per day, 8 s per month) NTP (internet time): depending on internet latency, typical <0.1 s absolute to UTC GPS: <1 ms absolute to UTC |
Read more: Fluke 1777 Three-Phase Power Quality Analyzer with current probes
Designed specifically for load studies, panel capacity, energy and power consumption studies, the Fluke 1730 models are versatile three-phase power loggers. The instrument comes with 3 Fluke 1730-iFlex® 1500 current probes, 150/1500 A range. 3000 Ampere and 6000 Ampere probes are also available. The 1730 model is equipped with wireless Fluke Connect.
Package
Basic Package |
Pricing |
FLUKE 1730 Power Logger System Complete with the
|
Rent & Purchase: |
Electrical Characteristics
Voltage inputs | 4 (3 phases and neutral) max voltage 1000 Vrms, CF 1.7 Impedance 10 MΩ |
Current inputs | 3 (mode selected automatically for the attached sensor) Clamp input: 500 mVrms/50 mVrms; CF 2.8 Rogowski coil input:150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
Frequency | Range: 42.5 Hz to 69 Hz Resolution 0.01 Hz Accuracy: ± (0.1 %) |
Voltage | Range: 1000 VAC Resolution: 0.1 V Accuracy: ± (0.2 % + 0.01 %) |
Power factor | Range: 0 <= PF <=1 Resolution: 0.01 Accuracy: ± 0.025 |
Physical Characteristics
Dimensions & Weight | 1730: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) 1730: 1.1 kg (2.5 lb) Power supply: 400 g (0.9 lb) |
Operating environment | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
Operating temperature and humidity | -10 °C to +50 °C (14 °F to 122 °F) 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH 40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH |
Enclosure protection | IP50 in accordance with EN60529 |
Designed specifically for load studies, panel capacity, energy and power consumption studies, the Fluke 1736/38 models are versatile three-phase power loggers. The instrument comes with 3 Fluke 1730-iFlex® 1500 current probes, 150/1500 A range. 3000 Ampere and 6000 Ampere probes are also available. The 1736/38 model is equipped with wireless Fluke Connect.
Instruments
Instrument | Description | Price |
Fluke 1736 | with 1500A 3.5" probes | Contact for price |
Fluke 1738 | with 1500A 3.5" probes | Contact for price |
Electrical Characteristics
Voltage inputs | Four (3 phases and neutral) Max 1000 Vrms, CF 1.7 Impedance 10 MΩ |
Current inputs | Four (Mode selected automatically for attached sensor) Clamp: 500 mVrms/50 mVrms; CF 2.8 Rogowski coil: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range |
Frequency | Range: 42.5 Hz to 69 Hz Resolution: 0.01 Hz Accuracy: ± (0.1 %) |
Voltage | Range: 1000 V Resolution: 0.1 V Accuracy: ± (0.2 % + 0.01 %) |
Physical Characteristics
Dimensions & Weight | Instrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in) Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in) Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in) Instrument: 1.1 kg (2.5 lb) Power supply: 400 g (0.9 lb) |
Operating environment | 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV) |
Operating temperature and humidity | min/max -10 °C to +50 °C (14 °F to 122 °F) 10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH 30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH 40 °C to 50 °C (104 °F to 122 °F) max. 45 % RH |
Enclosure protection | IP50 in accordance with EN60529 |